Optomod indoor cables FRNC/LS0H

optomod

I-K(ZN)H, flame retardant,



Optomod indoor cable frnc/ls0h

pic_1.gif (184 Byte)FRNC/LSOH sheath pic_3.gif (204 Byte)Aramid yarn strain relief pic_5.gif (204 Byte)Semi-loose buffer tube
pic_2.gif (207 Byte) Rip cord pic_4.gif (210 Byte)Strength member (GFK) pic_6.gif (202 Byte)Fibre
 
Cable type 2 x 1 4 x 1 6 x 1 8 x 1 10 x 1 12 x 1 16 x 1 20 x 1 24 x 1

nom. cable diameter [mm] 5.9 5.9 5.9 5.9 7.1 7.1 7.8 7.8 9.0

max. weight [kg/km] 37 37 37 37 49 50 63 64 73

min. bending radius [mm] 75 75 75 75 85 85 95 95 100

max. tensile load [N] 700 700 700 700 700 700 700 700 700

max. continuous crush resistance [N/cm] 50 50 50 50 50 50 50 50 50

max. short-term crush resistance [N/cm] 200 200 200 200 200 200 200 200 200

max. fire load [kWh/km] 207 204 201 199 302 299 338 332 464

 

Type
Optomod I n...x1..., FRNC/LSOH

I-K(ZN)H n...

Applications
Cable for connections between floors, can be laid on cable platforms, parapet ducts, vertical shafts and parapet channels, can be spliced in cable terminal distributors, direct terminal installation

Characteristics
2 - 24 semi-loose buffer tubes
Æ 0.9 mm, stranded with filler and strength member, small outside diameter, easy to install, ripcord for opening the sheath

Fire Behaviour
To IEC 332-1 and IEC 332-3, halogen free, flame retardant, FRNC/LS0H, non corrosive fumes


Print
Dätwyler Optomod, fibre count, fibre type, fibre dimension, cable number, meter marks, wave lines receiver

Sheath colour
Violett


Optical Properties
The cable is available with different types of fibre
(see fibre data sheets).



Temperature Range
Operation:  -25 °C to +60 °C
EN 187000; method 601

Mechanical Properties


ZTensile performance:
EN 187000 method 501


QCrush resistance:
EN 187000 method 504


Repeated bending:
EN 187000 method 507


Torsion:
EN 187000 method 508


Cable bending:
EN 187000 method 513, test 1

Ordering example:
2 km Optomod-I 24x1 G50, FRNC/LS0H
Technical changes without notice.